MULTIFUNCTION CALIBRATOR
OCM 140
This
Calibrator is bus compatible multifunction calibrator for precise generation
DC – and AC Currents up to 2OA, Power and Energy, cos F freely
selectable, Nickel and Platinum RTDs and Thermocouples, Resistors, Capacitors
and Frequencies and have output ports GPIB,IEEE488 and RS 232 with digital
camera for automatic calibration.
|
|
PROCESS HANDLED CALIBRATOR
OCM 502
It is a handled Calibrator-Multimeter
for generating currents of 0/4-20mA in a source or a sink mode, and
voltage from 0-10V. External voltages ±2V, ±20V or ±200V
(firm ranges or autorange) or currents up to ±100mA can be measured
during the calibrator generates the signals. The instruments features
a self calibration procedure accessable via the keyboard. The calibrator
is powered from a rechargeable battery which permits an uninterrupted
operation for 4 to 5 hours.
|
|
|
IMPEDANCE CALIBRATOR
OCM 500B
This
calibrator is a laboratory instruments for calibration of RLC bridges.
It contains nine resister standards from 100m0hm to 10 MOhm, seven capacitor
standards 1mH to 10H. The setting is in decade steps. The connection
to the device under test is with 4 wire BNC connectors. The calibration
of the instrument can be performed with the keyboard at the front and
is protected with a password against unauthorized entry. All calibrator
functions may also be controlled via the GPIB bus.
|
|
THREE
PHASE CALIBRATOR
OCM 103
OCM
103 is bus compatible three-phase calibrator for precise calibrator
of power and energy measuring electronic instruments, voltage and ampere
meters, phase meters, integrators, power transmitters and many others.
It also finds its application at laboratories, design and service departments
as well as at the institutions, which have to frequently calibrate their
equipment in accordance with their internal quality certification system.
|
|
|
AC AND DC CURRENT CALIBRATOR
OCM 150S
This
is precision Current Calibrator for DC and AC – currents from
9A to 105A within a frequency can be selected in 6 firm ranges. The
current can be set with a 4½ digit resolution. A control input
permits the settings of the output current with external control signals.
The form of the output current is identical with the form of the control
signal. By using an optional current coil, the output current can be
boost up to 1000 A. The setting of the output parameters is with the
keys at the front or with the GPIB Data Bus.
|
|
MULTIFUNCTION
CALIBRATOR
OCM 141
This is a bus compatible multifunction
calibrator for precise generation of DC and AC Currents up to 2A, Thermocouples,
RTDs and Resistors with RS 232 or IEEE488 output port. Mainly designed
for calibration by manufactures of electronic instrumentation.
|
|
|
MULTIFUNCTION
CALIBRATOR
OCM 140i
This is bus compatible multifunction calibrator
for precise generation DC – and AC- Voltages up to 1000 V and
DC and AC Currents up to 20A and Thermocouple type R,S,B,J,K,T,E,N with
output port RS 232.
|
|
HIGH RESISTANCE DECADE
OCM 109R
This is a precision four digit high resistance
decade for testing and calibration of Mega ohm-Meters, instruments for
testing of isolation resistances, measuring of input impedances of signal
conditioners etc. The decades can be set from 1M-0hm with switches at
the front or via the serial data port RS232. The maximum applied voltage
is 5kv. The decade is supplied with internal rechargeable battery.
|
|
|
PRECISION RESISTANCE DECADE SIMULATOR
OCM 622
This
is a high accuracy and high stability resistance decade. It is designed
as a temperature simulator as decade. In the temperature mode the instrument
simulates RTD Sensors within a range from -200 C to +850 C. Thermometers
Pt-100, Pt-200, Pt-500, Pt-1000, Ni-100 and Ni-1000 can be selected.
The required temperature value is entered with the keyboard or via the
data port. The corresponding resistance is the data port. The corresponding
resistance in a available at 2, 3 or 4 wire output terminals. In the
variable resistance mode the instrument permits a direct selection of
resistance in a range from 1 0hm to 1.2 MOhm. The resolution depends
on the resistance value selected. The resolution depends on the resistance
value selected. The highest resolution is 0.000010hm. The selected resistor
is available at 2 or 4 wire output terminals. A Soft Manager for Windows
at a diskette is suitable the communication via RS232 or IEEE488 Data
Bus. It permits the selection of the resistance from a PC or from a
supervising controller. An LCD displays informs about the selected parameters
and the control status.
|
|
BRAKE TESTER
CT-3010
It is a precision instrument for measurement
and diagnostics of brake systems of street and railway vehicles in dependence
of the power applied to the power applied to the brake pedal of the
air of hydraulic system. Apart of the momentary deceleration values
measured during the vehicles test also the average deceleration within
the entire test distance will be measured and calculated. The internal
memory is capable of storing up to 128 measurements which can later
be downloaded to a PC and evaluated under Windows.
|
|
|
CAPACITANCE
DECADE
OCM 520
It is a high precision high stability
Capacitance Decade. With the five decades switches at the front or via
the serial data port the values can be set from 100pF to 12uF with a
five digit resolution. A Soft Manager for a remote operation is running
under Windows.
|
|
RTD
SIMULATOR & RESISTANCE DECADE
OCM 612
This
is a high accuracy and stability resistance decade. It is designed as
a temperature simulator as well as a programmable low value resistance
decade. In the Ni-100 and Ni-1000 are simulated within a range from
- 200ºC to +850ºC. The temperature is entered with the keyboard
or via the serial data port. In the variable resistance mode the instrument
permits a direct selection of resistance in a range from 16 0hm to 10
k0hm with a resolution of up to 0.0001 0.hm. For a remote control via
RS232 the Soft Manager for Windows is available.
|
|